24 hour timer, 7 Day Timer ATP1006-3

24 hour timer, 7 Day Timer ATP1006-3

(The time switch can be automatically
adjusted according to the latitude and longitude of the switching time.)

24 hour timer 7 Day Timer ATP1006-3
Product Name: 24 hour timer 7 Day Timer ATP1006-3
Price: $10.00

Voltage : 

1. Function and Scope

24 hour timer, 7 Day Timer ATP1006-3 (hereinafter referred
to as “time switch”) is mainly used as time control elements in the circuit
with AC frequency of 50Hz, rated control power voltage of 220V at most and DC
current of 3A at most, such as being used to regularly control switch-on and
off of street lamps, advertising light boxes and other equipments, the product
may be used to adjust the switch-on and off time everyday according to the
latitude.

The product complies with the requirements
of Standard GB 14048.5 and IEC 60947-5-1.

2. Model and Its Meaning: ATP1006-3

3. Normal Operating Condition and Installation Condition

3.1 Ambient air humidity: -5℃~+40℃, and the
average temperature is no more than +35℃ in 24h.

3.2 Altitude: no more than 2,000m.

3.3 Humidity: the relative air humidity of
the installation site shall be no more than 50% when the maximum temperature is
+40℃, while it can be higher under lower temperature. Special measures shall be
taken for the condensation occasionally formed due to temperature change.

3.4 Pollution level: 3.

3.5 In the medium with explosion hazard and
no gas that is enough to corrode metal and destroy the insulation and the place
shall not have severe conductive dust.

3.6 In the place where is provided with
anti-snow and anti-rain equipment but not be full of water steam.

3.7 In the place without significant shake,
shock and vibration.

3.8 Installation class: II.

3.9 Transport and Storage Conditions: -25℃
to +55℃.

3.10 Power voltage change scope: 85%~110%
rated operating voltage.

3.11 Protection grade: IP20.

4 Main Technical Parameters

4.1 Rated control power voltage: 50Hz
AC220V.

4.2 Conventional thermal current: Ith 16A.

4.3 Category of the control circuit: AC-15.

4.4 Rated working current (Ie):
AC-15 220V 3A.

4.5 Timing error: ≤1s/d.

4.6 Time control scope: 1min~168h.

4.7 Dimension setting range: N/S -60 ° +60 °.

4.8 Mechanical life: ≥30,000 times.

4.9 Electric endurance: ≥10,000 times.

4.10 Installation method: Device installed,
guide tracked.

4.11 Anti-interference tolerance sees Table
1.

Table
1 Anti-interference Tolerance

Item

Severity

Static
discharge tolerance

8 ×
(1±10%) KV (air discharge)

Electromagnetic
radiation tolerance

Test
field strength 10 × (1±10%) V/m

Fast
transient tolerance

For
power line: 2 × (1±10%)KV,
duration 1min

Surge
(shock) tolerance

For
power line:1 × (1±10%)KV

RF
conduction tolerance

Open
circuit test voltage 10V, frequency scope 150kHz~80MHz

Voltage
sage tolerance

Sag
30% in half a cycle, sag 60% in 5 cycles and 50 cycles, sag 100% in 250
cycles

5 Outline, Installation Dimension and
Wiring Method

5.1 Outside dimension and installation
dimension see Figure 1.

24 hour timer 7 Day Timer ATP1006-3


a) ATP1006-3 outside dimension                    b)
ATP1006-3 installation imension

Figure
1 Outside dimensions and installation dimensions of ATP1006-3

5.2 Wiring method

5.2.1 Direct control method

Power of the controlled appliance is
supplied in single-phase, of which the working current is no more than the
rated value of this switch. Direct control method may be adopted, wiring method
see Figure 2; for light load with great starting current impact, please adopt
AC contactor expansion control method.

5.2.2 Single-phase expansion method

The controlled appliance is power supplied
in single-phase, of which the working current exceeds the rated value of this
switch. Please adopt AC contactor expansion control method, see Figure 3.

5.2.3 Three-phase operating method

Power of the controlled appliance is
supplied in three-phase, so external AC contactor is required hereof.

a) The coil voltage of the controlled
contactor is AC 220C 50Hz, so its wiring method sees

Figure 4;

b) The coil voltage of the controlled contactor is AC 380V 50Hz, so
its wiring method sees

Figure 5.

24 hour timer 7 Day Timer ATP1006-3

Figure 2 Direct single-phase controlled
wiring diagram   Figure 3 Single-phase expansion controlled wiring
diagram

24 hour timer 7 Day Timer ATP1006-3

Figure 4 Three-phase controlled wiring diagram (220V
for contactor coil)   Figure 5 Three-phase controlled wiring diagram
(3800V for contactor coil)

6 Setting and Use

This product
panel is set with five buttons, namely “MD (mode)”, “R (recall)”, “24 hour timer 7 Day Timer ATP1006-3 (left)”, “24 hour timer 7 Day Timer ATP1006-3 (-)” and “24 hour timer 7 Day Timer ATP1006-3 (+)”, so it can adjust
correspondingly hour (h), minute (min) and date; if there is some operating
indication, time switch may be controlled manually or automatically.

6 Setting and Use

This product
panel is set with five buttons, namely “MD (mode)”, “R (recall)”, “24 hour timer 7 Day Timer ATP1006-3 (left)”, “24 hour timer 7 Day Timer ATP1006-3 (-)” and “24 hour timer 7 Day Timer ATP1006-3 (+)”, so it can adjust correspondingly
date (d), latitude (24 hour timer 7 Day Timer ATP1006-3),
hour (h) and minute (min), and it can also set second (sec) in clock status.

6.1 Setting
process for timing switch parameters (see Figure 6).

6.2 Setting processes are as follows:

6.2.1 Firstly power-on or press button “MD”
+ “R” to enter latitude setting interface

6.2.1.1 Current latitude and date
adjustment

6.2.1.2 Press “24 hour timer 7 Day Timer ATP1006-3”,  “24 hour timer 7 Day Timer ATP1006-3” and “24 hour timer 7 Day Timer ATP1006-3” to adjust latitude, for example, local
latitude 30°N shall be adjusted to “N: 30”; while local latitude 15°S shall be
adjusted to “S: 15”, see Figure 7.

24 hour timer 7 Day Timer ATP1006-3

Figure
7

6.2.1.3 Press
“MD” to enter current date adjust status, press “24 hour timer 7 Day Timer ATP1006-3” to select the adjusted position, press “24 hour timer 7 Day Timer ATP1006-3” and “24 hour timer 7 Day Timer ATP1006-3” to plus and minus, adjust the
display date of the product to current date, such as current March 15 shall be
set to “03: 15d”, see Figure 8. After setting, press “MD” to exit.

24 hour timer 7 Day Timer ATP1006-3

Figure 8

6.2.2 Current time adjustment

6.2.2.1 Press
button “MD” for 3s to cancel the keyboard lockout, so that “LOCK” may
disappear, the current “min” position flashes, you can press “24 hour timer 7 Day Timer ATP1006-3” to select the adjusted position
and press “24 hour timer 7 Day Timer ATP1006-3” and “24 hour timer 7 Day Timer ATP1006-3” to plus and minus, so
as to adjust the display time to the current time, see

Figure 9.

24 hour timer 7 Day Timer ATP1006-3

Figure
9

 

6.2.3 Timing parameters (switch-on/off
time) setting

6.2.3.1 After finish operation in 6.2.2,
press “MD” to set the timing parameters, and the corresponding position
flashes, see Figure 10.

24 hour timer 7 Day Timer ATP1006-3

Figure
10

6.2.3.2 1ON
(first switch-on) time setting: press “24 hour timer 7 Day Timer ATP1006-3”,
24 hour timer 7 Day Timer ATP1006-3” and “24 hour timer 7 Day Timer ATP1006-3” respectively to set 1ON
time, the latitude marks the latitude adjustment function; after setting
hour, press 24 hour timer 7 Day Timer ATP1006-3” to enter latitude mark setting
model, by then, screen does not flash, and press “24 hour timer 7 Day Timer ATP1006-3” and “24 hour timer 7 Day Timer ATP1006-3”  to switch on/off the latitude
adjustment function; after finishing this, press “MD” to enter 1OFF (first
switch-off) time setting, see Figure 11.

24 hour timer 7 Day Timer ATP1006-3

Figure 10

6.2.3.3 1OFF (first switch-off) time
setting: set 1OFF time according to steps specified in 6.2.3.2.

6.2.3.4 Continue
to press “MD”, the screen will display   “24 hour timer 7 Day Timer ATP1006-3

24 hour timer 7 Day Timer ATP1006-3

Figure
12

6.2.4 After
setting, press “MD” for 3s, enter operation state, the time switch locks
automatically, “LOCK” shows, and see Figure 13.

24 hour timer 7 Day Timer ATP1006-3

Figure
13

6.3 After locking the switch, press “MD”
and “24 hour timer 7 Day Timer ATP1006-3” at the same
time to switch manual/automatic status. Continuously press the combination, the
screen will show “OFF”, “AUTO OFF”, “ON” and “ON AUTO” successively, see Figure
14. When the circuit shall be on and off temporarily in the process of
operation, the combination buttons can be used to adjust the switch to ON and
OFF; if the time switch shall work automatically according to the set time, the
combination button shall be used to adjust the switch to “ON AUTO” or “AUTO
OFF, then the time switch may work as set time, so as to achieve automatic
control, see Figure 14.

24 hour timer 7 Day Timer ATP1006-3

Figure
14 Manual/automatic time switch setting process

7 Notes

7.1 The switch into the line can only be
connected to AC220V power supply, do not access the other power.

7.2 If you can not achieve automatic control functionCheck the lower right corner of
the screen (AUTO) is right shown?

7.3 The internal battery can only provide
the LCD screen display and settings, such as A1, A2 terminal auxiliary power
missed, is unable to drive the relay output..

7.4 If the user find errors in the productsThrough short 3, 4 terminal resetAfter reset procedures need to
set again.

7.5 If the latitude function of some group
of setting time is open, the set time may be automatically adjusted by changing
the current latitude and date, so please check once more the set time after
changing the latitude and date.

7.6 When the end of the product life,
please recycle work product or its components, for not recycled parts, please
dispose of, to protect our environment.